FEATURES/:
● Portable, mid-range EMC test system for design integrity testing
● Resident capabilities for compliance testing up to 7 IEC/EN standards
● Also addresses many ANSI/IEEE, ITU, ETSI and UL standards
● Surge testing to 6kV with Combination, Telecom, and Ring Waves
● EFT testing to 4kV
● Monitors surge voltage and current at the output terminals
● Monitors output of the coupling unit and automatically switches connections according to coupling mode
The Thermo Scientific™ EMCPro PLUS™ EMC Test System isthe answer to manufacturers’ demands for a mid-range, multi-capability EMC immunity test instrument. It operates via our easy-to-use Microsoft Windows®-based PC software or from the front panel, and is easily configured to meet immunity standards required for CE Marking and related global regulatory compliance testing requirements. A portable and low-cost test instrument solution, the EMCPro PLUS system isideal for companies who require integrated test capability and versatility.
The EMCPro PLUS features surge testing to 6kV with the most common surge requirements: Combination Wave, Telecom Wave and Ring (Oscillatory) Wave. The EMCPro Plus can also be configured for custom test protocols to meet specific test requirements using the software and a full line of options and accessories, which include 3ø AC/DC Mains and I/O line Coupling/Decoupling, Networks, Magnetic Field Monitors, Magnetic Loop Coil, EFT Verification Loads, Differential High Voltage Probes and more.
Model: PRO-BASE System
Operating Voltage: 90-240VAC, 50/60Hz
Integrated EUT Mains Coupler/Decoupler (CDN): AC Voltage: 1 phase, 50 - 250 VAC Frequency: 50/60 Hz DC Voltage: 100 VDC, Max Current: 16 A, Max AC @250VAC 10A, Max DC to 100VDC 16A, Max to 48VDC
EUT Connectors: NEMA, British, Schuko, India, Australia, China
Control Interface: Manual Via Front Panel VDU Computer Via RS232/USB Fiber-optic interface
Safety Features: External Interlock for users Interlock for CCL connector External stop input
Environmental Operating Conditions: Temperature +15°C to +40°C Humidity 10 - 75%, non-condensing Altitude 8000 ft. maximum
Physical Specifications: Height: 22.9 cm (8.7 in) Width: 43.4 cm (17.1 in) Depth: 64.8cm(25.5in)
Weight: 39 kg (85 lb) CE Marking: Safety (LVD) and EMC Directives
Surge Waveform Monitoring: Monitors are switched automatically to match generator coupling mode. Voltage monitor provides 1000:1 ±10% attenuation factor Current monitor provides 200:1 ±10% attenuation factor
Option | Description |
---|---|
CCL | Capacitive Coupling Clamp conforming to IEC 61000-4-4, Ed.3 |
CCL-VERIFY | Capacitive Coupling Clamp Transducer Plate for verification of capacitive clamp, conforming to IEC 61000-4-4, Ed.3 |
CCLC | Capacitive Coupling Clamp Cover |
CM-3CD-EFT/32 | Three phase, 32A External CDN for EFT |
CM-3CD-SRG/32 | 3-phase, 32A External CDN for Surge |
CM-I/OCD | External 8-wire coupler/decoupler for I/O signal lines |
CM-TELCD | External coupler for Telecom Lines. |
EFT-ATTN-CAL | For EFT verification: Set of one 50Ω and one 1000Ω precision loads having >400MHz BW, one 20dB Attenuator with 1GHz BW |
PK1001D | Differential High Voltage Probes |
PQF-QUAL | Optional circuit per IEC 61000-4-11 to verify in-rush current of AC source to the PQF |
PRO-EFT | EFT Testing per IEC 61000-4-4, Ed.3; EN 61000-4-4; ANSI C62.41.2; ANSI C62.45 |
PRO-HPOWER | Power Frequency Magnetic Field per IEC 61000-4-8, Ed. 2 and EN 61000-4-8 |
PRO-HPULSE | Pulse Magnetic Field per IEC 61000-4-9, Ed. 2 & Ed. 1.1 and EN 61000-4-9 |
PRO-PQF | Voltage Dips, Interruptions per IEC 61000-4-11, Ed.2 |
PRO-RING | Surge per IEC 61000-4-5, Ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A & B, UL 1449 Ed. 3 Sect. 37; ANSI C62.45 |
PRO-SURGE | Surge per IEC 61000-4-5, Ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A & B, UL 1449 Ed. 3 Sect. 37; ANSI C62.45 |
PRO-TELECOM | Surge per IEC 61000-4-5, Ed. 3, EN 61000-4-5 |