TDS220 Tektronix Digital Oscilloscope
Additional Features:
Bandwidth: 100 MHz
2 Channels
1 GS/s Sample Rate on all Channels
Record Length: 2.5 kpts
Dual Timebase
Automatic Measurements
Multi-language User Interface
Autoset
Waveform and Setup Memories
Extended Capabilities Are Provided with Optional Modules, Software and Probing Applications
Applications:
Design and Debug
Service and Repair
Manufacturing Test and Quality Control
Education and Training
Signal Acquisition System
Sensitivity (with calibrated fine adjustment): 2 mV to 5V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode).
Vertical Zoom: Vertically expand or compress a live or stopped waveform
Automatic Measurements: Period, Frequency, Cycle RMS, Mean, Peak to Peak
Acquisition Modes: Sample, Average, Peak Detect: High frequency and random glitch capture; captures glitches as narrow as 10 ns using acquisition hardware at all time/div settings between 5 μs/div and 5 s/div
Calibrated Position Range
Volts/Div Setting: 2 mV to 200 mV/div; Offset Range: ±2 V; >200 mV to 5 V/div; Offset Range: ±50 V
Calibrated Position Range
Volts/Div Setting: 2 mV to 200 mV/div; Offset Range: ±2 V; >200 mV to 5 V/div; Offset Range: ±50 V
Time Base System (Main and Window)
Horizontal Zoom: Horizontally expand or compress a live or stopped waveform
Time/Division Range: 5 ns to 5 s/div
Record Length: 2500 sample points per channel
Horizontal Accuracy: ± 0.01%
Non-Volatile Storage
Waveform Display: Two 2500 point reference waveforms
Waveform Storage: Two 2500 point reference waveforms (TDS 210, TDS 220), four 2500 point reference waveforms (TDS 224)
Setups: 5 front panel setups
Triggering System (Main Only)
Trigger Type: Edge (Rising or Falling), Video, Set to 50%
Video Trigger Type: Triggers on Fields or Lines from sync-negative composite video; triggers on broadcast standard NTSC, PAL, or SECAM video
Trigger Mode: Auto, Normal, Single Sweep
Trigger Source: TDS 210 and TDS 220: CH1, CH2, Ext, Ext/5. TDS 224: CH1, CH2, CH3, CH4
Trigger View: Displays trigger signal while trigger view button depressed
Cursors
Types: Voltage, Time
Measurements: ΔT, 1/ΔT, ΔV
Waveform Processing
Arithmetic Operators: Add, Subtract
Sources: CH1 ± CH2, CH3 ± CH4
Autoset: Single button automatic setup on selected input signal for vertical, horizontal, and trigger systems
Display System
Robust, backlit LCD with adjustable multilevel contrast
Interpolation: Sin(x)/x
Modes: Vector, Dots, Dot Persistence
Format: YT and XY
Hardcopy Capability
Printer/File Formats: Thinkjet, Deskjet, Laserjet, Epson (9 or 24 pin), BMP, PCX, IMG, EPS, DPU 411, DPU 412
Hardcopy Layout: Landscape or Portrait
Environmental and Safety
Temperature: 0° C to +50° C (operating); -20° C to +60° C (non-operating)
Humidity: Up to 90% RH at or below +40° C; Up to 60% RH from 41° C to 50° C (operating and non-operating)
Altitude: Up to 2000 m (operating)
Electromagnetic Emissions: Meets Directive 89/336/EEC for Electromagnetic Compatibility; FCC Code of Federal Regulations, 47 CFR, Part 15, Subpart B, Class A
Safety: UL 3111, EN61010, CAN/CSAC22.2 No. 1010.1-92.
The TDS 200 Oscilloscopes have quickly become the benchmark for low-cost oscilloscopes. Offering an unbeatable combination of performance, reliability and versatility, the TDS 200 Series offers breakthrough digital and real-time advantages at low-cost analog oscilloscope prices.
REQUEST A QUOTE